Frame material
6063-T6
Shielding effectiveness
Construction of honeycomb panel | 200 KHz | 100 MHz | 500 MHz | 2 GHz | 10 GHz |
---|---|---|---|---|---|
Field | H | E | P | P | P |
Single honeycomb (3,2x6,35 mm) | 39 | 80 | 55 | 52 | 61 |
Single honeycomb (3,2x12,7 mm) | 78 | 100 | 55 | 96 | 80 |
Double honeycomb (2x3,2x6,35 mm, shifted by 90°) | 71 | 105 | 93 | 94 | 82 |
Item number
As honeycomb vent panels are generally manufactured according to customer drawings no standard item numbers are available for these products.
On request, our experts will prepare a detailed production drawing for you.